chilled water header

English to French Tech/Engineering Engineering: Industrial chilled water header
Hello,

I am trying to find the correct translation from English into French of chilled water header

In the sentence "the Supply/Return Chilled water Header Valves is Mechanically Struck"


Thank you for the help

Discussion

Mayca Fernandes Santos (asker) Feb 28, 2023:
CONTEXT: Emergency Operations Procedure for CRAH (computer room air handler) document.
The information I had about the "header" was "It’s a central connection for the chilled water pipes"

I also have for example " Chilled Water Header - Supply / Return Motorized Valves Fail to Open /Communication Failure"
florence metzger Feb 26, 2023:
nourrice ne convient pas au contexte de return supply... par contre collecteur d'alimentation et collecteur de retour sont cohérents...
Tony M Feb 24, 2023:
@ Florence That is one version of 'nourrice', though I think here you are actually looking at 'nourrice en charge'.
BUT we have already had several questions (and I have encountered the term in my own documents) on 'nourrice', where it was definitely nothing like a 'header tank', so I think there is a wider range of possible meanings.
florence metzger Feb 24, 2023:
nourrice/caisse en charge : header tank...
header : collecteur
florence metzger Feb 23, 2023:
la vanne du collecteur ......
Renate Radziwill-Rall Feb 23, 2023:
term Header Valves

Proposed translations

-1
36 mins

Conduite d'eau de refroidissement

Bonjour Mayca,

La bonne traduction au vu du contexte est: Conduite d'eau de refroidissement

https://project-haystack.org/doc/proto/chilled-water-header-...

J'espère vous avoir aidé.
Peer comment(s):

disagree Tony M : A 'header' is more than just a 'pipe' / and this is also not 'cooling' water.
1 hr
Something went wrong...
-1
1 hr

Collecteur d'eau de refroidissement

Bonjour,

"Header" est généralement traduit par "collecteur" en français.

Le collecteur forme un point central d'où partent ou viennent plusieurs circuits dans un circuit de chauffage/refroidissement.


Cdt,

Anthony
Note from asker:
I thought it was "eau réfrigérée" but found also "eau froide"
Peer comment(s):

disagree Tony M : This is not 'cooling water', but 'cooled water' — quite a different concept!
1 hr
True! Tough not quite different since it might be on the cooled side of the cooling circuit. But indeed you're right, "cooled water" = "eau refroidie" or "eau réfrigérée".
Something went wrong...
-1
2 hrs

clapet d'eau réfrigérée

Ce serait bien de savoir de quoi il s'agit, le contexte est important ! Je dirais que " le clapet d'alimentation/retour d'eau réfrigérée est inversé mécaniquement ".... mais pas sûr du tout
Note from asker:
Hi Olivier, it's a Emergency Operations Procedure for CRAH (computer room air handler) document
Peer comment(s):

disagree Tony M : 'header' can't be translated as 'clapet', which wouldn't make sense in the context here, no more than your suggested translation would. I think your idea amounts to over-interpretation here.
1 day 6 hrs
Something went wrong...
+1
2 hrs

nourrice d'eau réfrigérée

There seems to be something grammatically awry with the ST sentence: 'valves is'??
This kind of makes me suspect a non-native writer, which in turn makes me wonder about the use of the verb 'to strike' here?
Anyway, in the sense of a supply header, 'nourrice' is commonly used; not quite so confident about its use for the return side of things.
And normally, 'chilled' water would be 'réfrigérée', since it means water that has been deliberately lowered in temperature, so not just 'froide' = (not heated) or 'frâiche' (= pleasantly cool or fresh)

--------------------------------------------------
Note added at 8 days (2023-03-04 13:39:16 GMT)
--------------------------------------------------

Note that a 'header' is most usually used on the supply side (whence my suggestion of 'nourrice') — but if this is being used for both supply and return sides, then you might need to consider splitting the term an using e.g. 'collecteur' for the return side.
Note from asker:
Hello Tony it's a Emergency Operations Procedure for CRAH (computer room air handler) document
Peer comment(s):

agree Samuel Clarisse
8 days
Merci, Samuël !
Something went wrong...

Reference comments

5 days
Reference:

DEFINITION computer room air handler (CRAH)

https://www.techtarget.com/searchdatacenter/definition/compu...
A computer room air handler (CRAH) is a device frequently used in data centers to deal with the heat produced by equipment. Unlike a computer room air conditioning (CRAC) unit that uses mechanical refrigeration to cool the air in a data center, a CRAH uses fans, cooling coils and a water chiller system to remove heat.

--------------------------------------------------
Note added at 5 ημέρες (2023-03-01 11:26:59 GMT)
--------------------------------------------------

https://www.calorifuge-msci.com/fr/prestations-de-calorifuge...
Calorifugeage des réseaux d'eau glacée et mixte
Choisir le bon type de calorifugeage est essentiel pour s'adapter au mieux au type d'installation et aux besoins.

Pour éviter les déperditions énergétiques et optimiser la performance de votre installation, il est fortement recommandé de procédé à la mise en place d'un calorifugeage efficace sur vos tuyaux. Dans le cas d'un réseau d'eau glacée ou mixte, il est important de s'attarder sur la création d'une isolation permettant de limiter la condensation de l'eau hors des tuyaux.

Il faut dire que les réseaux froids (aussi appelés réseaux négatifs) sont très exigeants en matière d'isolation calorifuge.

Le Calorifuge des Réseaux Eau Glacée consiste à isoler une tuyauterie de type acier noir ou un matériel de synthèse par exemple une tuyauterie multicouche, en acier carbone, en PVC pression, en cuivre, Mapress, Instaflex... Pour ce faire, il convient notamment de choisir le bon matériau pour enrober les tuyauteries et l'appareillage (groupe frigorifique) afin d'améliorer durablement et rapidement la performance énergétique d'un logement ou d'un bâtiment entier.

Entreprise spécialiste calorifugeur installée à Saint-Laurent-du-Var près de Nice et Cannes, MSCI vous dit tout sur le calorifugeage de vos réseaux d'eaux glacées et mixtes.





--------------------------------------------------
Note added at 6 ημέρες (2023-03-01 14:13:27 GMT)
--------------------------------------------------

https://www.lc-thermic.com/service/professionnels/installati...
Installation réseaux eau glacée
L’eau glacée correspond à une eau générée par un groupe frigorifique, qui diffuse le froid via des émetteurs(cassettes). Une isolation de réseaux eau glacée permet d’éviter la condensation de votre tuyauterie.